Features and Benefits
-
Redundant dual 24 VDC power
inputs
-
Relay output warning for power
failure and port break alarm
-
Broadcast storm protection
-
Transparent transmission of VLAN
tagged packets
-
-40 to 75˚C operating
temperature range (T models)
Introduction
The EDS-316 are 16-port Ethernet
switches that provide an economical
solution for your industrial
Ethernet connections. The built-in
relay warning function alerts
network engineers when power
failures or port breaks occur, and
the switches are designed for harsh
industrial environments, such as in
hazardous locations (Class I, Div.
2/ATEX). The switches comply with
FCC, TÜV, UL, and CE standards, and
come in two model types. Standard
operating temperature range models
(0 to 60°C) and wide operating
temperature range models (-40 to
75°C). Both models undergo a 100%
burn-in test to ensure that they
fulfill the special needs of
industrial automation control
applications. The EDS-316 switches
can be installed easily on a
DIN-Rail or in a distribution box. |
|
• Technology: |
|
Standards |
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
and 100BaseFX
IEEE 802.3x for Flow Control |
|
Processing Type |
Store and Forward |
|
Flow Control |
IEEE802.3x full duplex, back
pressure flow control |
|
• Interface: |
|
RJ45 Ports |
10/100BaseT(X) auto
negotiation speed,Full/Half
duplex mode, and auto MDI/MDI-X
connection |
|
Fiber Port(s) |
100BaseFX ports (SC/ST
connector) |
|
LED Indicators |
PWR1, PWR2, Fault, 10/100M (TP
port), 100M (Fiber port) |
|
DIP Switches |
Port break alarm mask |
|
Alarm Contact |
1 relay output with current
carrying capacity of 1A @ 24
VDC |
|
• Optical Fiber |
 |
|
• Physical Characteristics: |
|
Housing |
Metal, IP30 protection |
|
Weight |
1140 g |
|
Dimensions |
80.5 x 135 x 105 mm (3.16 x
5.31 x 4.13 in) |
|
Installation |
DIN-Rail mounting, wall
mounting (with optional kit) |
|
• Environmental Limits: |
|
Operating Temperature |
Standard Models: 0 to 60°C
(32 to 140°F)
Wide Temp. Models: -40 to
75°C (-40 to 167°F) |
|
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
|
Ambient Relative Humidity |
5 to 95% (non-condensing) |
|
• Power Requirements: |
|
Input Voltage |
24 VDC (12 to 45 VDC),
redundant inputs |
|
Input Current |
EDS-316: 0.27 A @ 24 V
EDS-316-M/S/MM/SS/MS: 0.44 A
@ 24 V |
|
Overload Current
Protection |
1.6 A |
|
Connection |
1 removable 6-pin terminal
blocks |
|
Reverse Polarity
Protection |
Present |
|
• Agency Approvals: |
|
EMI |
FCC Part 15, CISPR (EN55022)
class A |
|
EMS |
EN61000-4-2 (ESD), level 3
EN61000-4-3 (RS), level 3
EN61000-4-4 (EFT), level 3
EN61000-4-5 (Surge), level 3
EN61000-4-6 (CS), level 3 |
|
Safety |
UL508, UL60950-1, EN60950-1 |
|
Hazardous Location |
UL/cUL Class I, Division 2,
Groups A, B, C and D; ATEX
Zone 2, Ex nC IIC |
|
Shock |
IEC60068-2-27 |
|
Freefall |
IEC60068-2-32 |
|
Vibration |
IEC60068-2-6 |
|
MTBF (meantime between
failures) |
Time: 257,000 hrs
Database: MIL-HDBK-217F, GB
25°C |
|
Maritime |
DNV, GL |
|
|