Features and Benefits
-
PCCC objects for
Rockwell Automation
networks supported
-
ProCOM provides a
virtual serial port for
multiple DF1 and
EtherNet/IP device
communication
-
8 simultaneous EtherNet/IP
clients with up to 16
simultane ous requests
per client
-
Serial redirector
function provided
-
Embedded EtherNet/IP and
DF1 protocol analyzer
-
Redundant dual DC
power inputs
-
Built-in Ethernet
cascading for easy
wiring
Overview
MGate™ EIP3000 series
products provide 1 or 2-port
DF1 to EtherNet/IP protocol
conversion for users who
need to connect Allen
Bradley PLCs to an
EtherNet/IP network, and
provide a cost-effective way
to combine PLC and SCADA
software into the same
system.
Protocol Conversion between
DF1 and EtherNet/IP
MGate™ EIP3000 series
products can be used to
connect DF1 devices and
EtherNet/IP devices to
provide Allen Bradley PLCs
with remote maintenance
capability. By supporting
PCCC objects on CIP, the
MGate™ EIP3000 can
communicate seamlessly with
Rockwell Ethernet devices.
The EIP3000 protocol
gateways come with either 1
or 2 serial ports to allow
users to select a suitable
gateway depending on the
size of the network.
Support for Multiple
EtherNet/IP Connections
The MGate™ EIP3000 series
products support up to 8
EtherNet/IP clients and 8
EtherNet/IP servers
simultaneously. Each client
can send up to 16 requests
at one time.
Windows Utility for Easy
Setup and Traffic Monitoring
Moxa provides a
user-friendly Windows
utility with multiple
language support for use
with all of our MGate™
products. The utility also
supports a traffic
monitoring function for
EtherNet/IP and DF1
protocols.

Serial Redirector Function
Provided
The MGate™ EIP3000 series
products have a serial
redirector function that
allows additional options
for DF1 network integration.
The serial redirector
function allows the commands
of a serial master (command
initiator) to be redirected
to the serial slave (command
executor) on another port.
In addition, a serial master
can operate simultaneously
with EtherNet/IP Clients or
other serial masters without
altering the DF1
architecture or software.
Using the serial redirector
function, EIP3000 gateways
can establish redundant
backup control or EtherNet
monitoring of DF1 networks
that were originally
designed for a single serial
master.
ProCOM—Virtual Serial Port
for Multiple DF1 and
EtherNet/IP Device
Communication
Each MGate™ EIP3000
gateway supports a virtual
serial port. A remote PC
uses a Moxa-provided Real
COM or TTY driver to connect
to the EIP3000's virtual
serial port. RSLinx and
SCADA systems can use the
virtual COM port to
communicate with an EIP3000
gateway. The virtual serial
port function gives RSLinux
or some SCADA systes the
capability to connect to
multiple DF1 and EtherNet/IP
devices through a protocol
gateway.
Pull high/low Resistors and
Terminator Selection
When using termination
resistors to prevent serial
signal reflection, it is
important to set the pull
high/low resistors correctly
so that the electrical
signal is not corrupted.
Since no set of resistor
values is universally
compatible with all
environments, the EIP3000
has DIP switches on the
bottom panel for setting the
termination and pull
high/low resistor values.
Built-in Isolation
Complex device networks
that incorporate high
amperage devices could be
subject to electrical signal
distortion from electrical
discharges, magnetic noise,
or common mode transients.
MGate™ series products solve
this problem by using
built-in optical isolation.